TMA-WIN10-2.2.38

Ensure 'Shut down the system' is set to 'Administrators, Users'

HighLevel 1Automatedwindows

Description

This policy setting determines which users who are logged on locally to the computers in your environment can shut down the operating system with the Shut Down command. Misuse of this user right can result in a denial of service condition. The recommended state for this setting is: Administrators, Users.

How it is checked

Audit method: Shell command

shell
$f = Join-Path $env:TEMP ('tmaegis-' + [guid]::NewGuid().ToString() + '.inf'); secedit /export /cfg $f /areas SECURITYPOLICY USER_RIGHTS /quiet | Out-Null; $c = Get-Content $f -ErrorAction SilentlyContinue; Remove-Item $f -Force -ErrorAction SilentlyContinue; $line = $c | Where-Object { $_ -match '^\s*SeShutdownPrivilege\s*=' } | Select-Object -First 1; $v = if ($line) { ($line -split '=', 2)[1].Trim().Trim('"') } else { $null }; $have = @(if ($v) { $v -split ',' | ForEach-Object { $_.Trim().TrimStart('*') } | Where-Object { $_ } }); if ((($have | Sort-Object -Unique) -join ',') -eq 'S-1-5-32-544,S-1-5-32-545') { 'compliant' } else { 'non-compliant: ' + ($have -join ',') }
Expected output
compliant

How it is fixed

Fix method: Guidance or infrastructure patch

Set through Group Policy (domain policy for domain members): Computer Configuration\Policies\Windows Settings\Security Settings\Local Policies\User Rights Assignment\Shut down the system

Properties

Operating systems
windows-10
Tags
cis-convertedseceditwindows
Reference
CIS Microsoft Windows 10 Enterprise Benchmark v4.0.0 - 2.2.38

Check this host

Run this on a machine you are allowed to audit. The scan is read-only.

shell
tmaegis scan --target windows