TMAegis
Aturan lainnya untuk windows

TMA-WIN10-2.2.38

Ensure 'Shut down the system' is set to 'Administrators, Users'

TinggiLevel 1Otomatiswindows

Deskripsi

This policy setting determines which users who are logged on locally to the computers in your environment can shut down the operating system with the Shut Down command. Misuse of this user right can result in a denial of service condition. The recommended state for this setting is: Administrators, Users.

Cara pemeriksaan

Metode audit: Perintah shell

shell
$f = Join-Path $env:TEMP ('tmaegis-' + [guid]::NewGuid().ToString() + '.inf'); secedit /export /cfg $f /areas SECURITYPOLICY USER_RIGHTS /quiet | Out-Null; $c = Get-Content $f -ErrorAction SilentlyContinue; Remove-Item $f -Force -ErrorAction SilentlyContinue; $line = $c | Where-Object { $_ -match '^\s*SeShutdownPrivilege\s*=' } | Select-Object -First 1; $v = if ($line) { ($line -split '=', 2)[1].Trim().Trim('"') } else { $null }; $have = @(if ($v) { $v -split ',' | ForEach-Object { $_.Trim().TrimStart('*') } | Where-Object { $_ } }); if ((($have | Sort-Object -Unique) -join ',') -eq 'S-1-5-32-544,S-1-5-32-545') { 'compliant' } else { 'non-compliant: ' + ($have -join ',') }
Output yang diharapkan
compliant

Cara perbaikan

Metode perbaikan: Panduan atau patch infrastruktur

Set through Group Policy (domain policy for domain members): Computer Configuration\Policies\Windows Settings\Security Settings\Local Policies\User Rights Assignment\Shut down the system

Properti

Sistem operasi
windows-10
Tag
cis-convertedseceditwindows
Referensi
CIS Microsoft Windows 10 Enterprise Benchmark v4.0.0 - 2.2.38

Periksa host ini

Jalankan ini pada mesin yang diizinkan untuk Anda audit. Pemindaian bersifat hanya baca.

shell
tmaegis scan --target windows