TMA-WIN10-2.2.38
Ensure 'Shut down the system' is set to 'Administrators, Users'
HochStufe 1Automatisiertwindows
Beschreibung
This policy setting determines which users who are logged on locally to the computers in your environment can shut down the operating system with the Shut Down command. Misuse of this user right can result in a denial of service condition. The recommended state for this setting is: Administrators, Users.
So wird geprüft
Prüfmethode: Shell-Befehl
shell
$f = Join-Path $env:TEMP ('tmaegis-' + [guid]::NewGuid().ToString() + '.inf'); secedit /export /cfg $f /areas SECURITYPOLICY USER_RIGHTS /quiet | Out-Null; $c = Get-Content $f -ErrorAction SilentlyContinue; Remove-Item $f -Force -ErrorAction SilentlyContinue; $line = $c | Where-Object { $_ -match '^\s*SeShutdownPrivilege\s*=' } | Select-Object -First 1; $v = if ($line) { ($line -split '=', 2)[1].Trim().Trim('"') } else { $null }; $have = @(if ($v) { $v -split ',' | ForEach-Object { $_.Trim().TrimStart('*') } | Where-Object { $_ } }); if ((($have | Sort-Object -Unique) -join ',') -eq 'S-1-5-32-544,S-1-5-32-545') { 'compliant' } else { 'non-compliant: ' + ($have -join ',') }- Erwartete Ausgabe
compliant
So wird behoben
Behebungsmethode: Anleitung oder Infrastruktur-Patch
Set through Group Policy (domain policy for domain members): Computer Configuration\Policies\Windows Settings\Security Settings\Local Policies\User Rights Assignment\Shut down the system
Eigenschaften
- Betriebssysteme
- windows-10
- Tags
- cis-convertedseceditwindows
- Referenz
- CIS Microsoft Windows 10 Enterprise Benchmark v4.0.0 - 2.2.38
Diesen Host prüfen
Führen Sie dies auf einem Rechner aus, den Sie prüfen dürfen. Der Scan ist schreibgeschützt.
shell
tmaegis scan --target windows