TMAegis베타
fortiswitch 관련 규칙 더 보기

Fortinet FortiSwitch

TMA-FORTISWITCH-1.5.2.1

Ensure the latest firmware is installed

높음레벨 2수동 검토fortiswitch

설명

Check against the Fortinet website to make sure that the latest stable firmware is installed.

점검 방법

감사 방식: 수동 검토

이 권장 사항은 자동으로 점검할 수 없습니다. --include-manual 옵션을 전달하면 스캔 결과에 이 지침과 함께 표시됩니다.

First, check for the latest firmware version available going to https://support.fortinet.com and login. Go to Support -> Firmware Download. Select your product and click on Download for the latest available versions. Second, verify the current firmware on your system. In the CLI: get system status ... Version: FortiSwitch-108F v7.4.6,build0895,250129 (GA) ... In the GUI: 1. Go to System > Config > Firmware 2. Check the Current Running Firmware. At the same time, go to https://www.fortiguard.com/psirt?product=FortiSwitch and check for vulnerabilities that your existing version might have.

조치 방법

조치 방식: 가이드 또는 인프라 패치

Download the required FortiSwitchOS firmware/s. Go to https://support.fortinet.com and login. Go to Support -> Firmware Download. Once there select the product. Check the latest firmware version available and choose the firmware for your specific model of the hardware. Click on "HTTPS" and "Checksum" next to your model to download the code and checksum. The last step is to install the new firmware. It is recommended to use GUI to perform this task as it would be much easier. In the GUI 1. Go to System > Config > Firmware 2. Under Upgrade File click on Choose File... 3. Then click on "Apply".

속성

운영 체제
모두
태그
fortiswitchupdates
참고 자료
CIS FortiSwitch Benchmark v1.0.0 - 1.5.2.1 Ensure the latest firmware is installed