Windows (desktop and server)
TMA-WIN10-2.2.22
Ensure 'Force shutdown from a remote system' is set to 'Administrators'
Description
This policy setting allows users to shut down Windows Vista-based or newer computers from remote locations on the network. Anyone who has been assigned this user right can cause a denial of service (DoS) condition, which would make the computer unavailable to service user requests. Therefore, it is recommended that only highly trusted administrators be assigned this user right. The recommended state for this setting is: Administrators.
How it is checked
Audit method: Shell command
$f = Join-Path $env:TEMP ('tmaegis-' + [guid]::NewGuid().ToString() + '.inf'); secedit /export /cfg $f /areas SECURITYPOLICY USER_RIGHTS /quiet | Out-Null; $c = Get-Content $f -ErrorAction SilentlyContinue; Remove-Item $f -Force -ErrorAction SilentlyContinue; $line = $c | Where-Object { $_ -match '^\s*SeRemoteShutdownPrivilege\s*=' } | Select-Object -First 1; $v = if ($line) { ($line -split '=', 2)[1].Trim().Trim('"') } else { $null }; $have = @(if ($v) { $v -split ',' | ForEach-Object { $_.Trim().TrimStart('*') } | Where-Object { $_ } }); if ((($have | Sort-Object -Unique) -join ',') -eq 'S-1-5-32-544') { 'compliant' } else { 'non-compliant: ' + ($have -join ',') }- Expected output
compliant
How it is fixed
Fix method: Guidance or infrastructure patch
Set through Group Policy (domain policy for domain members): Computer Configuration\Policies\Windows Settings\Security Settings\Local Policies\User Rights Assignment\Force shutdown from a remote system
Properties
- Operating systems
- windows-10
- Tags
- cis-convertedseceditwindows
- Reference
- CIS Microsoft Windows 10 Enterprise Benchmark v4.0.0 - 2.2.22
Check this host
Run this on a machine you are allowed to audit. The scan is read-only.
tmaegis scan --target windows