TMAegisBeta
Weitere Regeln für cisco-asa

Cisco ASA

TMA-CISCO-ASA-1.2.4

Ensure 'Unused Interfaces' is disable

MittelStufe 1Manuelle Prüfungcisco-asa

Beschreibung

Disables the unused interfaces. Shutting down the unused interfaces is a complement to physical security. In fact, an attacker connecting physically to an unused port of the security appliance can use the interface to gain access to the device if the relevant interface has not been disabled ... Not reliably checkable from an exported configuration. Reported as SKIP with review instructions.

So wird geprüft

Prüfmethode: Manuelle Prüfung

Diese Empfehlung kann nicht automatisch geprüft werden. Ein Scan führt sie mit diesen Anweisungen auf, wenn Sie --include-manual übergeben.

Not reliably checkable from an exported configuration. - Step 1: Run the following command to check if there are unsused ports that have not been disabled. hostname#sh int ip brief | in __down Example: This first command lists all the interfaces Corp-FW# show int ip brief Interface IP-Address OK? Method Status Protocol GigabitEthernet0/1 unassigned YES unset up up GigabitEthernet0/1.201 172.16.61.1 YES CONFIG up up GigabitEthernet0/1.202 172.16.62.171 YES CONFIG up up GigabitEthernet1/0 unassigned YES unset administratively down down GigabitEthernet1/1 unassigned YES unset ...

So wird behoben

Behebungsmethode: Anleitung oder Infrastruktur-Patch

! - Step 1: Identify the physical name <interface_physical_name> of the unused interfaces that are not disabled - Step 2: For each of the identified interfaces, run the following command interface <interface_physical_name> shutdown

Eigenschaften

Betriebssysteme
Beliebig
Tags
cisco-asanetworkhardening
Referenz
CIS Cisco ASA 9.x Firewall Benchmark v1.1.0 - 1.2.4 Ensure 'Unused Interfaces' is disable