TMA-MSSQL-2.7
Ensure 'Remote Admin Connections' Server Configuration Option is set to '0'
中级别 1自动化mssql
说明
The remote admin connections option controls whether a client application on a remote computer can use the Dedicated Administrator Connection (DAC). Clustered instances are not applicable and are reported compliant. Default: By default, this option is disabled (0), only local connections may use the DAC. Runs one sqlcmd query with its defaults (Windows authentication to the local default instance); set SQLCMDSERVER, SQLCMDUSER and SQLCMDPASSWORD for another instance or SQL authentication. Needs VIEW SERVER STATE / sysadmin-level read access.
检查方式
审计方法: SQL 查询
sql_query
sqlcmd -b -h -1 -W -Q "SET NOCOUNT ON; SELECT CASE WHEN CAST(SERVERPROPERTY('IsClustered') AS int) = 1 THEN 'compliant' WHEN EXISTS (SELECT 1 FROM sys.configurations WHERE name = 'remote admin connections' AND CAST(value AS int) = 0 AND CAST(value_in_use AS int) = 0) THEN 'compliant' ELSE 'noncompliant' END;"- 预期输出
compliant
修复方式
修复方法: SQL 语句
shell
sqlcmd -b -h -1 -W -Q "SET NOCOUNT ON; EXEC sp_configure 'remote admin connections', 0; RECONFIGURE;"属性
- 操作系统
- 任意
- 标签
- mssqldatabasesurface-areadac
- 参考
- CIS Microsoft SQL Server 2025 Benchmark v1.0.0 - 2.7 Ensure 'Remote Admin Connections' Server Configuration Option is set to '0'
检查本机
请在您有权审计的机器上运行此命令。扫描为只读操作。
shell
tmaegis scan --target mssql