IBM AIX
TMA-AIX-8.1.3
Ensure modification to TE system is audited
Açıklama
At Level 1, Trusted Execution (TE) should be actively monitoring for applications not yet allowlisted. The recommendation for this is in section two. Additionally, the AIX AUDIT system needs to be configured for modifications to the TE subsystem. Modification to security mechanisms need to be monitored to maintain system integrity. Audit: automated read-only check derived from the CIS audit procedure; it prints "compliant" when the control is met.
Nasıl denetlenir
Denetim yöntemi: Kabuk komutu
out=$(grep -E "^[[:blank:]]*default[[:blank:]]*=" /etc/security/audit/config 2>/dev/null) || exit 1; r=compliant; for p in '(=|,)[[:blank:]]*TE_Untrusted([[:blank:]]*,|[[:blank:]]*$)' '(=|,)[[:blank:]]*TE_FileWrite([[:blank:]]*,|[[:blank:]]*$)' '(=|,)[[:blank:]]*TE_Policies([[:blank:]]*,|[[:blank:]]*$)' '(=|,)[[:blank:]]*TEAdd_Stnz([[:blank:]]*,|[[:blank:]]*$)' '(=|,)[[:blank:]]*TEDel_Stnz([[:blank:]]*,|[[:blank:]]*$)' '(=|,)[[:blank:]]*TESwitch_algo([[:blank:]]*,|[[:blank:]]*$)' '(=|,)[[:blank:]]*TEQuery_Stnz([[:blank:]]*,|[[:blank:]]*$)'; do printf '%s\n' "$out" | grep -Eq -- "$p" || r="missing: $p"; done; echo "$r"- Beklenen çıktı
compliant
Nasıl düzeltilir
Düzeltme yöntemi: Kılavuz veya altyapı yaması
Ensure AUDIT Trusted Execution events are in the class default. 1. Edit the file /etc/security/audit/config 2. Find the stanza named classes: 3. If the class default does not exist add a line with: default = TE_Untrusted,TE_FileWrite,TE_Policies,TEAdd_Stnz,TEDel_Stnz,TESwitch_algo,TEQ uery_Stnz 4. If the class default already exists ensure the following audit events are included in the class definition TE_Untrusted,TE_FileWrite,TE_Policies,TEAdd_Stnz,TEDel_Stnz,TESwitch_algo,TEQ uery_Stnz
Özellikler
- İşletim sistemleri
- Herhangi biri
- Etiketler
- aixaudit
- Referans
- CIS IBM AIX 7 Benchmark v1.2.0 - 8.1.3 Ensure modification to TE system is audited
Bu ana makineyi denetle
Bunu denetleme izniniz olan bir makinede çalıştırın. Tarama salt okunurdur.
tmaegis scan --target aix