TMAegisBeta
Više pravila za yugabytedb

YugabyteDB

TMA-YUGABYTEDB-3.1.11

Ensure the correct messages are written to the server log

SrednjaNivo 1Automatskayugabytedb

Opis

The log_min_messages setting specifies the message levels that are written to the server log. Each level includes all the levels that follow it. The lower the level (vertically, below), the fewer messages are sent. Runs ysqlsh (add the YugabyteDB bin directory to PATH) against PGHOST/PGPORT (default 127.0.0.1:5433) as PGUSER (default yugabyte); supply the password through PGPASSWORD or ~/.pgpass. Passes when log_min_messages is warning or more verbose.

Kako se proverava

Metod provere: SQL upit

sql_query
out=$(ysqlsh -h "${PGHOST:-127.0.0.1}" -p "${PGPORT:-5433}" -U "${PGUSER:-yugabyte}" -d "${PGDATABASE:-yugabyte}" -tAc "SELECT CASE WHEN lower(current_setting('log_min_messages')) IN ('debug5','debug4','debug3','debug2','debug1','info','notice','warning') THEN 'compliant' ELSE 'noncompliant' END" 2>/dev/null) || exit 1; printf '%s\n' "$out"
Očekivani izlaz
compliant

Kako se ispravlja

Metod ispravke: Smernica ili zakrpa infrastrukture

Set it with the YB-TServer GFlag --ysql_pg_conf_csv="log_min_messages='warning'" on every YB-TServer and restart it.

Svojstva

Operativni sistemi
Bilo koji
Oznake
yugabytedblogging
Referenca
CIS YugabyteDB Benchmark v2.0.0 - 3.1.11 Ensure the correct messages are written to the server log

Proverite ovaj računar

Pokrenite ovo na računaru za koji imate dozvolu za proveru. Skeniranje radi u režimu samo za čitanje.

shell
tmaegis scan --target yugabytedb