TMA-IIS-3.3
Ensure custom error messages are not off
Opis
When an ASP.NET application fails and causes an HTTP/1.x 500 Internal Server Error, or a feature configuration (such as Request Filtering) prevents a page from being displayed, an error message will be generated. Administrators can choose whether or not the application should display a friendly message to the client, detailed error message to the client, or detailed error message to localhost only. customErrors mode must be RemoteOnly or On (not Off) in the root web.config and every site. PowerShell 5.1 with the WebAdministration module; run elevated.
Kako se proverava
Metod provere: Komanda ljuske
Import-Module WebAdministration -ErrorAction Stop; $paths = @('MACHINE/WEBROOT') + @(Get-Website | ForEach-Object { "IIS:\Sites\$($_.Name)" }); $bad = @($paths | Where-Object { $c = Get-WebConfiguration -Filter 'system.web/customErrors' -PSPath $_; [string]$c.mode -eq 'Off' }); if ($bad.Count -eq 0) { 'compliant' } else { 'noncompliant' }- Očekivani izlaz
compliant
Kako se ispravlja
Metod ispravke: Smernica ili zakrpa infrastrukture
Set-WebConfigurationProperty -PSPath 'MACHINE/WEBROOT/APPHOST/<site>' -Filter system.web/customErrors -Name mode -Value RemoteOnly
Svojstva
- Operativni sistemi
- Bilo koji
- Oznake
- iisinformation-disclosure
- Referenca
- CIS Microsoft IIS 10 Benchmark v1.2.1 - 3.3 Ensure custom error messages are not off
Proverite ovaj računar
Pokrenite ovo na računaru za koji imate dozvolu za proveru. Skeniranje radi u režimu samo za čitanje.
tmaegis scan --target iis --level 2