Cisco IOS XR
TMA-CISCO-IOSXR-1.4.3
Set 'logging console critical'
Opis
Verify logging to device console is enabled and limited to a rational severity level to avoid impacting system performance and management. This configuration determines the severity of messages that will generate console messages. Logging to console should be limited only to those messages required for immediate troubleshooting while logged into the device. CIS marks this Manual; automated as a config-line check. Audited against the hierarchical output of 'show running-config' (run 'terminal length 0' first; not 'show running-config formal').
Kako se proverava
Metod provere: Obrazac konfiguracije
- Obrazac
(?m)^logging console critical\b
Kako se ispravlja
Metod ispravke: Smernica ili zakrpa infrastrukture
! Configure console logging level. logging console critical
Svojstva
- Operativni sistemi
- Bilo koji
- Oznake
- cisco-iosxrnetworklogging
- Referenca
- CIS Cisco IOS XR 7.x Benchmark v1.0.1 - 1.4.3 Set 'logging console critical'
Proverite ovaj računar
Pokrenite ovo na računaru za koji imate dozvolu za proveru. Skeniranje radi u režimu samo za čitanje.
tmaegis scan --target cisco-iosxr