TMAegisBeta
Više pravila za cisco-iosxr

Cisco IOS XR

TMA-CISCO-IOSXR-1.4.3

Set 'logging console critical'

SrednjaNivo 1Automatskacisco-iosxr

Opis

Verify logging to device console is enabled and limited to a rational severity level to avoid impacting system performance and management. This configuration determines the severity of messages that will generate console messages. Logging to console should be limited only to those messages required for immediate troubleshooting while logged into the device. CIS marks this Manual; automated as a config-line check. Audited against the hierarchical output of 'show running-config' (run 'terminal length 0' first; not 'show running-config formal').

Kako se proverava

Metod provere: Obrazac konfiguracije

Obrazac
(?m)^logging console critical\b

Kako se ispravlja

Metod ispravke: Smernica ili zakrpa infrastrukture

! Configure console logging level. logging console critical

Svojstva

Operativni sistemi
Bilo koji
Oznake
cisco-iosxrnetworklogging
Referenca
CIS Cisco IOS XR 7.x Benchmark v1.0.1 - 1.4.3 Set 'logging console critical'

Proverite ovaj računar

Pokrenite ovo na računaru za koji imate dozvolu za proveru. Skeniranje radi u režimu samo za čitanje.

shell
tmaegis scan --target cisco-iosxr