Ensure Admin idle timeout time is configured
説明
The idle timeout period is the amount of time that an administrator will stay logged in to the GUI without any activity. PASS requires admintimeout between 1 and 5 minutes. Audited against FortiSwitchOS 'show full-configuration' output (standalone FortiSwitch, saved in full); patterns are scoped to the named 'config ... end' block, whose member lines are indented.
チェック方法
監査方法: 設定パターン
- パターン
(?m)^config system global\n(?:[ \t]+[^\n]*\n)*?[ \t]+set admintimeout [1-5][ \t]*$
修正方法
修正方法: ガイダンスまたは IaC パッチ
config system global set admintimeout 5 end # CIS guidance: To change the idle timeout in the GUI: 1) Login to FortiSwitch with Super Admin privileges. 2) Go to 'System' > 'Admin' > 'Settings'. 3) In the 'Administration Settings' section, set the 'Idle Timeout' value to five minutes by typing 5. 4) Click 'Update'. To change the idle timeout in the CLI: config system global set admintimeout 5 end