Host must automatically terminate idle host client sessions

SedangLevel 1Otomatisvmware

Deskripsi

Configuring the host to automatically terminate idle host client sessions helps mitigate security risks associated with unattended sessions, which could potentially be exploited. The recommended setting for this control is a timeout value of 900. The parameter governing this behavior is UserVars.HostClientSessionTimeout. The audit reads UserVars.HostClientSessionTimeout with esxcli and requires 900 seconds or less (0 = unlimited fails). Runs in the ESXi Shell (busybox sh) as root.

Cara pemeriksaan

Metode audit: Perintah shell

shell
out=$(esxcli system settings advanced list -o /UserVars/HostClientSessionTimeout 2>/dev/null) || exit 1
v=$(printf '%s\n' "$out" | awk '$1=="Int" && $2=="Value:" {print $3; exit}')
case "$v" in ''|*[!0-9-]*) echo '/UserVars/HostClientSessionTimeout: no integer value'; exit 1 ;; esac
if [ "$v" -gt 0 ] && [ "$v" -le 900 ]; then echo compliant; else echo "/UserVars/HostClientSessionTimeout = $v (expected 1-900)"; fi
Output yang diharapkan
compliant

Cara perbaikan

Metode perbaikan: Panduan atau patch infrastruktur

1. Set the approved idle timeout with Get-VMHost | Get-AdvancedSetting -Name UserVars.HostClientSessionTimeout | Set-AdvancedSetting -Value <seconds> -Confirm:$false 2. Reconnect to the Host Client and confirm inactive sessions expire as expected.

Properti

Sistem operasi
Apa saja
Tag
vmwareesximanagement
Referensi
CIS VMware ESXi 9.0 Benchmark v1.0.0 - 3.17 Host must automatically terminate idle host client sessions

Periksa host ini

Jalankan ini pada mesin yang diizinkan untuk Anda audit. Pemindaian bersifat hanya baca.

shell
tmaegis scan --target vmware