TMA-MSSQL2022-2.15

Ensure 'AUTO_CLOSE' is set to 'OFF' on contained databases

FaibleNiveau 1Automatiséemssql

Description

AUTO_CLOSE determines if a given database is closed or not after a connection terminates. If enabled, subsequent connections to the given database will require the database to be reopened and relevant procedure caches to be rebuilt. Because authentication of users for contained databases occurs within the database not at the server\instance level, the database must be opened every time to authenticate a user. The frequent opening/closing of the database consumes additional server resources and may contribute to a denial of service.

Méthode de vérification

Méthode d'audit: Requête SQL

sql_query
sqlcmd -b -h -1 -W -Q "SET NOCOUNT ON; SELECT COUNT(*) FROM sys.databases WHERE containment <> 0 AND is_auto_close_on = 1;"
Sortie attendue
0

Méthode de correction

Méthode de correction: Recommandation ou correctif d'infrastructure

Execute the following T-SQL, replacing <database_name> with each database name found by the Audit Procedure: ALTER DATABASE <database_name> SET AUTO_CLOSE OFF;

Propriétés

Systèmes d'exploitation
Tous
Étiquettes
mssqlsqlserver-2022
Référence
CIS Microsoft SQL Server 2022 Benchmark v1.3.0 - 2.15 Ensure 'AUTO_CLOSE' is set to 'OFF' on contained databases

Vérifier cet hôte

Exécutez cette commande sur une machine que vous êtes autorisé à auditer. L'analyse est en lecture seule.

shell
tmaegis scan --target mssql