Fortinet FortiSwitch
TMA-FORTISWITCH-3.1.3.1
Encrypt Log Transmission to Syslog
Description
Enable encryption for logs that are sent to a SIEM, FortiAnalyzer, or FortiManager. PASS requires syslog mode reliable and enc-algorithm high in config log syslogd setting. Audited against FortiSwitchOS 'show full-configuration' output (standalone FortiSwitch, saved in full); patterns are scoped to the named 'config ... end' block, whose member lines are indented.
Méthode de vérification
Méthode d'audit: Motif de configuration
- Motif
(?m)^config log syslogd setting\n(?:(?:[ \t]+[^\n]*\n)*?[ \t]+set mode reliable[ \t]*\n(?:[ \t]+[^\n]*\n)*?[ \t]+set enc-algorithm high[ \t]*$|(?:[ \t]+[^\n]*\n)*?[ \t]+set enc-algorithm high[ \t]*\n(?:[ \t]+[^\n]*\n)*?[ \t]+set mode reliable[ \t]*$)
Méthode de correction
Méthode de correction: Recommandation ou correctif d'infrastructure
config log syslogd setting set mode reliable set enc-algorithm high end # CIS guidance: Secure log transfer settings can only be configured on CLI: config log syslogd setting set mode reliable set enc-algorithm high end
Propriétés
- Systèmes d'exploitation
- Tous
- Étiquettes
- fortiswitchlogging
- Référence
- CIS FortiSwitch Benchmark v1.0.0 - 3.1.3.1 Encrypt Log Transmission to Syslog
Vérifier cet hôte
Exécutez cette commande sur une machine que vous êtes autorisé à auditer. L'analyse est en lecture seule.
tmaegis scan --target fortiswitch