TMAegis
Más reglas para ros

TMA-ROS1-1.10

Disable rosmaster listening on all interfaces by default

AltaNivel 1Automatizadaros

Descripción

rosmaster is the handshaking server responsible for connecting publishers to subscribers and vice-versa. By default it listens on all interfaces on a given machine, including external interfaces. This greatly increases attack surface area, and is only required if one is using distributed computing (where multiple machines are running ROS and need to connect to the same master). The audit requires the ROS master port 11311 to listen only on loopback (ss); when rosmaster is not running it requires every running ROS 1 process to have ROS_HOSTNAME (or ROS_IP) set to localhost. Host-level control from the CIS ROS Melodic benchmark (Ubuntu 18.04 robot hosts); run as root.

Cómo se verifica

Método de auditoría: Comando de shell

shell
command -v ss >/dev/null 2>&1 || exit 1
l=$(ss -Hltn 'sport = :11311' 2>/dev/null) || exit 1
if [ -n "$l" ]; then bad=$(printf '%s\n' "$l" | awk '{print $4}' | grep -Ev '^(127\.[0-9.]+|\[::1\]|::1):11311$')
  [ -z "$bad" ] && echo compliant || echo "rosmaster listens on: $(printf '%s ' $bad)"; exit 0; fi
bad=0; for e in /proc/[0-9]*/environ; do env=$( (tr '\0' '\n' < "$e") 2>/dev/null ) || continue
  case "$env" in *ROS_DISTRO=melodic*|*ROS_MASTER_URI=*) ;; *) continue ;; esac
  h=$(printf '%s\n' "$env" | sed -n 's/^ROS_HOSTNAME=//p;s/^ROS_IP=//p' | head -n 1)
  case "$h" in localhost|127.0.0.1|::1) ;; *) echo "pid ${e#/proc/}: ROS_HOSTNAME/ROS_IP=${h:-unset}"; bad=1 ;; esac
done
[ "$bad" -eq 0 ] && echo compliant
Salida esperada
compliant

Cómo se corrige

Método de corrección: Guía o parche de infraestructura

Ensure the ROS_HOSTNAME environment variable is set to localhost, thereby ensuring rosmaster only listens on loopback and isn't accessible on the network. One can cover most user session services and applications by adding the following line to /etc/environment: ROS_HOSTNAME="localhost" Note that this will not cover systemd system units. If a unit is being created that runs rosmaster (e.g. roscore or roslaunch), make sure this environment variable is set by utilizing Environment=, EnvironmentFile=, or similar.

Propiedades

Sistemas operativos
Cualquiera
Etiquetas
rosros1melodicsystem
Referencia
CIS ROS Melodic Benchmark v1.0.0 - 1.10 Disable rosmaster listening on all interfaces by default

Verificar este host

Ejecute esto en un equipo que tenga permiso para auditar. El escaneo es de solo lectura.

shell
tmaegis scan --target ros